TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 45 of 624

2-29
TB 9-2510-251-13
21
22
20
23
2-1.1
Installation of Air Conditioning Kit to M998 and M998A1; M1037; M1097 and M1097A1
with GSIE Add-on-Armor (Cont’d).
d. Install Refrigerant Hoses (Cont’d)
Figure 2-39.
Condenser Connection
(15)
Connect Condenser.
a.
Four-door vehicles only:
Lubricate O-ring and install #6 female straight fitting on outlet
(smaller) fitting on condenser.
b.
Two-door vehicles only:
Lubricate O-ring and install #6 female 45° fitting (20) on outlet
(smaller) fitting on condenser.
c.
Lubricate O-ring and install #8 female straight fitting (21) to inlet (larger) fitting on
condenser.
d. Trim ends of #6 hose (22) from drier and connect to right fitting.
e. Trim ends of #8 hose (23) from compressor and connect to left fitting.
(16)
Reinstall plywood panel on top of transmission tunnel by notching around drain hoses and
refrigerant lines.


Back to Top