TB 9-3950-253-13&P
Change 1
0048-4
0048
CALIBRATION – CONTINUED
7. Press and hold HOOK DOWN button (
Figure 3, Item 3
) until inside of hook (
Figure 3, Item 1
) is just above top
of bail bar (
Figure 3, Item 2
). Release HOOK DOWN button.
Figure 3.
Inside of Hook Above Bail Bar.
048
8. Press and hold UNSTOW button (
Figure 4, Item 1
) until bail bar (
Figure 4, Item 3
) reaches back end of hook
(
Figure 4, Item 2
). Release UNSTOW button. Stowage guide is now in third calibration position.
Figure 4.
Bail Bar at Back End of Hook.
048
3
1
2
1
2
3