TM-10-5411-205-13

SHELTER, ELECTRICAL EQUIPMENT - 250/G

TECHNICAL MANUAL; OPERATOR’S, UNIT, AND DIRECT SUPPORT MAINTENANCE MANUAL

MAY 1995
CHANGE 2

  TM-10-5411-205-13 - Page 11 of 127

TM 10-5411-205-13
1-9. Location and Description of Major Components. (Figure 1-1)
1.
2.
3 .
4.
ITE M
DESCRIPTION
Door assembly
Provides personnel access to interior of shelter.
Inner (emergency) door assembly
Provides emergency personnel exit and allows fresh air to
enter shelter through an air vent with filter. The shielded
shelters are provided with an RFI/EMI filter.
Lifting bracket assembly
Provides hookup point for sling assembly when lifting
shelter and when securing shelter onto truck.
Towing bracket assembly
Provides hookup point for guide rope when guiding sling-
lifted shelter into position and when securing shelter onto
5. Recessed step pan assembly
6. Skid assemblies
truck.
Allows access to roof.
Permit a fully equipped shelter to be seated on rough
terrain. They also provide forklifting access.
Figure 1-1. Major Shelter Components.
1-10. Equipment Data.
Height
Widt h
Length
Gross weight
Cubage
Load on skids
70.125
in (178.11 cm)
79.0625 in (200.82 cm)
86.625 in (220.03 cm)
Shield 770 lb (349 kg) empty
Unshielded 782 lb (355 kg) fully loaded
Empty 1.8 psi
Fully loaded 6.2 psi
Change 1
1- 3