TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 179 of 389

TM 3-1040-279-12&P
a. Relay K103 or K203.
REMOVAL
1. Remove panel cover (P. 4-110).
NOTE
Removal and installation procedures are the
same for both relays.
2. Tag and remove electrical connections from relay K103 (1).
3. Remove four screws (2), washers (3), and nuts (4).
INSTALLATION
1. Position electromagnetic relay (1) in instrument panel (5), and secure with four screws (2),
washers (3), and nuts (4).
2. Attach electrical connections as tagged. See control panel wiring (P. 4-127).
3. Install panel cover (P. 4-110).
Change 2
4-111


Back to Top