CONTROL PANEL ASSEMBLY (CONT).
h.
Panel Light.
REMOVAL
1.
Remove panel cover (P. 4-110).
NOTE
Removal and installation procedures are the same for all panel lights. When
replacing right side center panel light, fire detection control unit must be
removed first (P. 4-122).
2.
Tag and unsolder electrical connections from panel light socket (1).
3.
Remove nut (2) and washer (3) from panel light socket (1) and remove socket from control panel
(4).
INSTALLATION
1.
Position panel light socket (1) in control panel (4) with lens opening facing in direction shown by
arrow. Secure panel light socket in control panel with nut (2) and washer (3).
2.
Solder electrical connections as tagged to panel light socket (1).
3.
Install lamp if required (P. 4-124).
4.
Install panel cover (P. 4-110).