TM-3-1040-279-12-P

GENERATOR SET, SMOKE, MECHANICAL: PULSE JET, M157 W/120 GAL FOG OIL TANK AND W/80 GAL FOG OIL TANK

TECHNICAL MANUAL; OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST AND DEPOT MAINTENANCE REPAIR PARTS

MAY 1987

  TM-3-1040-279-12-P - Page 185 of 389

TM 3-1040-279-12&P
9.
SMOKE TEMP Indicator.
REMOVAL
1.
Remove panel cover (P. 4-110).
NOTE
Removal and installation procedures are the same for SMOKE TEMP
indicator.
2.
Tag and remove electrical connections from SMOKE TEMP indicator (1).
3.
Remove three screws (2), washers (3) and nuts (4) and remove SMOKE TEMP indicator (1) with
gasket (5).
INSTALLATION
1.
Position SMOKE TEMP indicator (1) with gasket (5) in instrument panel (6) and secure with three
screws (2), washers (3) and nuts (4).
2.
Attach electrical connections as tagged to SMOKE TEMP indicator (1). Place lock washer (7) under
nut, and place terminal lug between the two flat washers (3).
3.
Install panel cover (P. 4-110).
Change 4
4-117


Back to Top