n. FIRE Warning Indicator.
REMOVAL
1. Remove
2. Tag and
panel cover (P. 4-110).
remove electrical connections from FIRE warning indicator (1).
3. Remove two screws (2) and clips (3) securing FIRE warning indicator (1) in control panel (4).
4. Pull lens (5) from FIRE warning indicator (1) and remove indicator from control panel.
INSTALLATION
1. Position FIRE warning indicator (1) in control panel (4) and push lens (5) into indicator.
2. Secure FIRE warning indicator (1) in control panel (4) with two clips (3) and screws (2).
3. Attach electrical connections to indicator as tagged.
4. Install panel cover (P. 4-110).