m. Check Valve.
REMOVAL
1. Remove air hose assembly (1) from check valve (2).
2. Remove check valve (2) from elbow (3) on air compressor (4).
3. Remove adapter (5) from check valve (2).
INSTALLATION
NOTE
Apply sealing compound to threads of male
pipe fittings before installing.
Position check valve with arrow pointing up.
1. Connect adapter (5) to check valve (2).
2. Connect check valve (2) to elbow (3).
3. Connect air hose assembly (1) to check valve (2).