Item
No.
3
(cont)
4
TM 3-1040-279-12&P
Table 2-1. Operator Preventive Maintenance Checks and Services (cont)
Interval
BEFORE,
AFTER
BEFORE,
AFTER
BEFORE,
M54 Smoke
AFTER
Generator
BEFORE,
AFTER
Location
Item to Check/
Service
Fuel Cans
(cont)
Procedure
b. Remove refueling cap (4)
on both 5-gallon fuel cans
(5) and check for water or
dirt in fuel. Clean fuel can
and fuel can lid assembly
strainer screen, if con-
taminated.
c.
Fill fuel cans to bottom of
fill hole in fuel can lid
assemblies with clean fuel
and secure refueling caps
(4).
Not Fully
Mission
Capable If:
a.
Check for signs of leaks in
all hoses, connectors, and
lines.
Check that hoses are
not torn, cracked,
twisted, or collapsed.
b. Check that cable
assemblies are correctly
connected and tight.
Check cable insulation
for dry rot, cuts, or
wear to bare wire.
Class III fog oil leaks are
present, or Class II and III fuel
leaks are present.
Hoses are torn, cracked, or
collapsed.
Cable connectors are broken.
Cable insulated is dry rotted,
cut, or worn to bare wire.
Change 4
2-7