4-210.2
Change 4
F
Remove stamped nut (10) and nut (11) from re-
ducer (9).
G
Remove roll pin (12) from pivot (13) and remove
actuator arm (2) from pivot (13) and base plate
(14).
H
Remove cable sheath (8) from straight adapter
(15).
I
Remove elbow (15) from base plate (14).
J
Pull wire rope (7) though nut (5), reducer (9),
nut (11), stamped nut (10), cable sheath (8), el-
bow (15), base plate (14), and actuator arm (2).
WARNING
Do
not
breathe
fire
extinguisher vapors.
Failure
to comply may result in injury
to personnel.
A
Remove cotter pin (1) from actuator arm (2).
B
Cut and remove antipilferage seal (3) and pull
fire extinguisher handle (4) outward from hull.
Discard antipilferage seal (3).
C
Remove nut (5) from fire extinguisher handle (4)
and pull wedge (6) and wire rope (7) free of nut
(5).
D
Remove wedge (6) from wire rope (7).
E
Remove cable sheath (8) from reducer (9).
Note
To remove wire rope it is necessary to re-
move the fire extinguisher handle nut and
wedge.
Note
Notice the routing of the wire rope to facilitate
reassembly.
REMOVAL (LEFT SIDE)