TM 5-2350-262-20-1
4-210.4
Change 4
F
Remove four self-locking screws (10) and wash-
ers (11) from access cover (12) and gasket (13).
Discard self-locking screws (10).
G
Remove stamped nut (14) and nut (15) from re-
ducer (9).
H
Remove roll pin (16) from pivot (17) and remove
actuator arm (2) from pivot (17) and base plate
(18).
I
Remove cable sheath (8) from straight adapter
(19).
J
Remove straight adapter (19) from base plate
(18).
K
Pull wire rope (7) through nut (5), reducer (9),
gasket (13), access cover(12),
nut (15), stamped
nut (14), cable sheath (8), straight adapter (19),
base plate (18), and actuator arm (2).
Discard
gasket (13).
WARNING
Do
not
breathe
fire
extinguisher vapors.
Failure
to comply may result in injury
to personnel.
A
Remove cotter pin (1) from actuator arm (2).
B
Cut and remove antipilferage seal (3) and pull
fire extinguisher handle (4) outward from hull.
Discard antipilferage seal (3).
C
Remove nut (5) from fire extinguisher handle (4)
and pull wedge (6) and wire rope (7) free of nut
(5).
D
Remove wedge (6) from wire rope (7).
E
Remove cable sheath (8) from reducer (9).
Note
To remove wire rope it is necessary to re-
move the fire extinguisher handle nut and
wedge.
Note
Notice the routing of the wire rope to facilitate
reassembly.
REMOVAL (RIGHT SIDE)
15
3
1
2
7
8
19
17
16
7
4
13
1
8
14
9
6
5
4
7
18
OUTSIDE
HULL
10
11
13
12