TM-5-2350-377-13-P

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST SUPPORTING THE HYDRAULIC BLADE FOLDER-TRACK TENSIONER

JUNE 2012

  TM-5-2350-377-13-P - Page 78 of 404

ELECTRICAL SYSTEM - Continued
STEP
5.
Check manifold wiring harness and hydraulic valve solenoids for continuity.
a.
Disconnect manifold wiring harness (Figure 3, Item 1) from control box (Figure 3, Item 4).
b.
Check continuity between all wiring harness connector pins (Figure 3, Item 2) at connector
(Figure
3,
Item
3). This will also check continuity of the appropriate valve solenoids.
c.
Refer to Table 1 for lead locations.
d.
If continuity is indicated, reconnect manifold wiring harness (Figure 3, Item 1) to control box
(Figure
3,
Item
4).
4
3
2
T00403HBF
1
Figure 3.
Manifold Wiring Harness Connector.
Table
1.
Manifold Wiring Harness Connector.
HARNESS CONNECTOR PIN
HARNESS CONNECTOR PIN
SOLENOID PLUG PINS
L
A
Z1U
L
B
Z1L
L
C
Z2U
L
D
Z2L
M
G
Z4U
M
H
Z4L
CONDITION/INDICATION
Is continuity present across manifold wiring harness?
DECISION
YES - If continuity is indicated, go to Step (7).
NO - If an open circuit is indicated, go to Step (6).
TM 5-2350-377-13&P
0012
0012-4


Back to Top