ELECTRICAL SYSTEM - Continued
STEP
7.
Check control box for continuity.
a.
Remove connector J-1 (Figure 5, Item 3) and connector J-2 (Figure 5, Item 2) from each end on control
box (Figure 5, Item 1).
b.
Check continuity between connector pins on connectors J1 (Figure 5, Item 3) and J2 (Figure 5, Item 2).
T00405HBF
1
2
3
Figure 5.
Control Box.
c.
Refer to Tables 2 through 5 for lead locations.
Table
2.
Control Box Connector Pins.
POSITIVE LEAD
NEGATIVE LEAD
J-1 (3)
J-2 (2)
J-1 (3)
J-2 (2)
C
D
L
E
M
A
C
L
M
CONDITION/INDICATION
Is continuity present across control box?
DECISION
YES - If continuity is indicated, go to Step (8).
NO - If an open circuit is indicated, replace control box wiring harness (WP
0027). Verify problem is solved.
TM 5-2350-377-13&P