TM-5-2350-377-13-P

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST SUPPORTING THE HYDRAULIC BLADE FOLDER-TRACK TENSIONER

JUNE 2012

  TM-5-2350-377-13-P - Page 83 of 404

ELECTRICAL SYSTEM - Continued
T00407HBF
1
4
2
3
Figure 7.
Track Loosening Switch.
Table
5.
Control Box Track Loosening Switch.
POSITIVE LEAD
NEGATIVE LEAD
J-1 (3)
J-2 (2)
J-1 (3)
J-2 (2)
C
A
C
C
D
A
C
C
CONDITION/INDICATION
Is continuity present at track loosening switch?
DECISION
YES - If continuity is indicated, go to Step (11).
NO - If an open circuit is indicated, replace control box wiring harness (WP
0027). Verify problem is solved.
TM 5-2350-377-13&P
0012
0012-9


Back to Top