TM-5-2350-377-13-P

ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; OPERATOR AND FIELD MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST SUPPORTING THE HYDRAULIC BLADE FOLDER-TRACK TENSIONER

JUNE 2012

  TM-5-2350-377-13-P - Page 86 of 404

ELECTRICAL SYSTEM - Continued
STEP
12.
Check control box switches for continuity.
a.
Remove control box wiring harness (Figure 9, Item 2) from switch connector pins (Figure 9, Item 1).
SW2
SW4
SW3
1 2 3 4 5 6
SW1
7 8 9 10
1
2
3
1
2
1
2
3
1
2
T00409HBF
2
1
Figure 9.
Control Box Wiring Harness.
b.
Check continuity between switch connector pins.
c.
Refer to Table 7 for lead locations.
TM 5-2350-377-13&P
0012
0012-12