TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 245 of 790

TM 5--2350--378--24&P
0013 00--20
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE --
Continued
0013 00
YES
from block 11
NO
YES
13
Replace solenoid valve V11 or V5,
on primary manifold, as applicable
(WP 0035 00).
14
Replace directional control valve (DCV) bank
(TM 5--2350--262--20--2).
12
Is transducer T--1 hydraulic pressure greater than
3,000 psi (20,684 kPa)?
Perform solenoid valve V11 or V5 (as applicable)
pressure check.
NO
from block 11
To block 15


Back to Top