TM 5--2350--378--24&P
0013 00--14
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE --
Continued
0013 00
YES
To block 9
To block 33
NO
NO
from block 2
8
Is transducer T--3 hydraulic pressure between 3,950--4,050
psi (27,235--27,925 kPa)?
Perform main relief valve pressure test using the HDC.