TM-5-2350-378-24-P

HYDRAULIC DIAGNOSTIC CENTER (HDC) SUPPORTING ARMORED COMBAT EARTHMOVER (ACE), M9

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

  TM-5-2350-378-24-P - Page 242 of 790

TM 5--2350--378--24&P
0013 00--17
FRONT CORNER (LEFT OR RIGHT) RAISES IN SPRUNG, BUT NOT UNSPRUNG MODE --
Continued
0013 00
MAIN PUMP FLOW TEST
NOTE
An insufficient flow of hydraulic oil is indicated if ejector requires
more than 32 seconds to fully extend or if apron requires more
than 15 seconds to fully raise.
Start engine and allow engine to idle (750--850 rpm).
With ejector fully retracted, hold EJECTOR CONTROL lever in FORWARD, and note
length of time required for ejector to fully extend.
With apron in full down position, move APRON CONTROL lever to UP, and note length
of time required for apron to fully raise. Lower apron.
Stop engine; relieve hydraulic pressure.


Back to Top