TM 5--2350--378--24&P
0038 00--3
REPLACE MANUAL SHUTOFF VALVE V23 -- Continued
0038 00
INSTALLATION
WARNING
S
Do not operate ejector when personnel are in bowl. Do not work in bowl unless
ejector lock is engaged. Failure to comply may result in severe injury or death to
personnel.
S
Do not stand or work in bowl area unless ejector lock is engaged. Do not stand in
bowl to observe roller guide travels. Failure to comply may result in severe injury
or death to personnel.
S
When folding dozer blade, work on blade latches from side of vehicle only. Do not
stand In front of dozer blade while retracting ejector. Failure to comply may result
in severe injury or death to personnel.
1.
At directional control valve bank (Figure 2, item 1) port 22 adapter (Figure 2, item 7), install new o--ring
(Figure 2, item 6) and manual shutoff valve V23 (Figure 2, item 2).
2.
Install new o--ring (Figure 2, item 3) and adapter (Figure 2, item 4) in bottom port of manual shutoff valve V23
(Figure 2, item 2).
3.
Connect hose (Figure 2, item 5) to bottom adapter (Figure 2, item 4) of manual shutoff valve V23 (Figure 2,
item 2).
Figure 2. Installing Manual Shutoff Valve V23
END OF TASK