TM 5-5420-202-20-2
ACCELERATOR CONTROL ROD REPLACEMENT (Sheet 3 of 5)
9.
Using pliers, remove three woodruff keys (R) from control rod (D).
CLEANING AND INSPECTION:
Dry cleaning solvent P-D-680 is toxic and flammable.
To prevent personal injury, wear
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don’t breathe vapors.
Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning solvent is 100°F (38°C) and for Type #2 is 138°F (50°C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
1.
2.
3.
4.
Using dry cleaning solvent and clean cloths, clean all parts.
Check all parts for bends, cracks, wear in holes, and other defects. Replace defective
parts.
Inspect bushings (A) for wear. Replace defective
bushings (A) if damaged.
Examine housing (B) for cracks.
Go on to Sheet 4