TM 5-5420-202-20-4
GENERAL MAINTENANCE (Sheet 28 of 33)
Safety Wiring Procedures (Sheet 2 of 2)
NOTE
Always use new lockwire.
NOTE
Drilled head bolts and screws installed with self-locking nuts or
lockwashers usually do not require safety wiring.
NOTE
Do not use lockwire to secure fasteners or fittings together
that are spaced more than 6 inches apart.
NOTE
Use care when installing lockwire to be sure it is tight but not
overstressed.
NOTE
When safety wiring castellated nuts on drilled studs, tighten nut
to low side of torque range (unless otherwise
specified) and
continue tightening until a slot alines with hole.
NOTE
Safety wire drain plugs and cocks to adjacent (less than 6 inches
away) bolts, nuts, or parts having a free lockhole.
NOTE
Safety wire electrical connectors which have threaded coupling
rings or plugs which have screws to fasten the individual parts
of the plug together .
Safety wire connectors and plugs
individually.
End of Task