HYDRAULIC FLUID FILTER ASSEMBLY REPAIR (Sheet 5 of 8)
CLEANING AND INSPECTION:
Cleaning agent specified is flammable. Use only in well ventilated areas. Keep away
from flames, sparks, or heat. Do not smoke while using. Prevent contact with eyes,
mouth, and/or skin. Wear rubber gloves when performing cleaning procedures.
1.
Using rags and dry cleaning solvent, clean all parts.
2.
Inspect parts for damage, wear, cracks, or deterioration.
Replace all defective parts.
ASSEMBLY:
1.
Manually install
2.
Manually install
far as possible.
3.
Manually install
4.
Manually install new preformed packing (F)
on cover (G).
5.
position cover (G) on housing (C).
6.
Using socket, install four lockwashers (H)
and screws (J) securing cover (G) to
housing (C).
Go on to Sheet 6
3-215