TM-5-5420-228-24

LAUNCHER HYDRAULICS SYSTEM M48A5/M60A1 TANK CHASSIS, TRANSPORTING: FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT; MAINTENANCE MANUAL

AUGUST 1985

  TM-5-5420-228-24 - Page 682 of 750

TM 5-5420-228-24
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 1 of 2)
TOOLS: Slip joint pliers, conduit style, with plastic jaw inserts
Flat-tip screwdriver
SUPPLIES:
Lockwasher
Gasket
REMOVAL:
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
NOTE
1.
2.
3.
Go
Removal procedures are the
same for both the left and right
dummy receptacles.
Using pliers, disconnect electrical
connect or (A) of discharger harness (B)
from back of discharger (C).
Using screwdriver, remove four screws (D)
and lockwashers (E) securing dummy
receptacle (F) and gasket (G) to discharger
bracket (H).
Take dummy receptacle (F) and gasket (G)
off discharger bracket (H).
on to Sheet 2
TA251748
4-100