TM 5-5420-228-24
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 2 of 2)
INSTALLATION:
WARNING
1.
2.
3.
4.
End
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
NOTE
Installation procedures are the
same for both the left and right
dummy receptacles.
Put dummy receptacle (A) and new
gasket (B) in position on back of discharger
bracket (C).
Using screwdriver, secure receptacle (A)
and gasket (B) to discharger bracket (C)
with four screws (D) and new lockwashers (E).
Connect electrical connector (F) of
discharger harness (G) to receptacle (H)
at back of discharger (J).
Per form smoke grenade launcher
functional check (TM 5-5420-202-20).
of Task
TA251749
4-101