TM-5-5420-228-24

LAUNCHER HYDRAULICS SYSTEM M48A5/M60A1 TANK CHASSIS, TRANSPORTING: FOR BRIDGE, ARMORED-VEHICLE-LAUNCHED; SCISSORING TYPE, CLASS 60

TECHNICAL MANUAL; ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT; MAINTENANCE MANUAL

AUGUST 1985

  TM-5-5420-228-24 - Page 683 of 750

TM 5-5420-228-24
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 2 of 2)
INSTALLATION:
WARNING
1.
2.
3.
4.
End
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
NOTE
Installation procedures are the
same for both the left and right
dummy receptacles.
Put dummy receptacle (A) and new
gasket (B) in position on back of discharger
bracket (C).
Using screwdriver, secure receptacle (A)
and gasket (B) to discharger bracket (C)
with four screws (D) and new lockwashers (E).
Connect electrical connector (F) of
discharger harness (G) to receptacle (H)
at back of discharger (J).
Per form smoke grenade launcher
functional check (TM 5-5420-202-20).
of Task
TA251749
4-101