TM 9–1200–215–34&P
6–13
6–14.
CCA MAINTENANCE INSTRUCTIONS CONTINUED
b.
INSTALLATION CONTINUED
1.
Attach ESD grounding strap to wrist and
ground, to ensure ESD protection.
2.
Place CCA plate spacer (1) so that plate
spacer and top cover (2) marks align.
Align
screw holes.
3.
Position two spacers (8) between CCA plate
spacer (1) and PCU Main CCA (3) and secure
to top cover with two screws (6) and two flat
washers (7).
Torque screws to 5.5 + .5 in.–lb
(0.62 + 0.1 N
S
m).
4.
Install 11 screws (4) and 11 flat washers (5)
securing PCU Main CCA (3) and CCA plate
spacer (1) to top cover (2).
Torque screws to
5.5 + .5 in.–lb (0.62 + 0.1 N
S
m).
5.
Install top cover assembly IAW procedure
outlined in paragraph 6–13.
4
5
3
1
2
7
7
6
6
8