12
Remove boot (24) from toggle switch (25).
13
14
15
16
17
18
NOTE
Perform the following steps only as necessary
for replacement of damaged or defective
parts.
Remove hexagon plain nut (26) from toggle switch
(25).
NOTE
Rotate elevation handwheel to move sector
gear away from toggle switch.
Using tape (item 20, appx B), tag and unsolder four
wires (27) from toggle switch (25).
Remove toggle switch (25) from housing.
Unsolder wire (28) from contact of connector (29).
Remove four screws (30), four lockwashers (31),
connector (29), and gasket (32) from housing.
Discard lockwashers and gasket.
Unsolder wire (27) from contact (33). Unscrew
contact (33) and screw thread insert (34) from
mount.
b. Repair
1
Remove corrosion, grease, and dirt from all parts.
Refer to TM 9-254 for cleaning instructions.
2
Visually inspect for missing or damaged parts.
3
Repair or replace parts in accordance with
authorized parts listed in appendix D.
Change 1
5.1-19


Back to Top