TM 9-1240-401-34&P
5.1-10. DIRECT SUPPORT TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
LOCATION
CORRECTIVE ACTION
LEVEL ASSEMBLY
1.
LEVEL VIALS (1) HAVE UNEVEN OR NO ILLUMINATION
WITH 24 VOLTS DC APPLIED.
Observe visually in darkened area with 24 volts DC
applied.
a.
Replace toggle switch (ref. para 5.1-14).
b.
Send to general support maintenance.
2.
LEVEL VIAL (1) HAS NO BUBBLE OR IS CRACKED.
Observe visually.
Replace level vial (ref. para 5.1-17).
COVER ASSEMBLY
3.
COUNTER DIALS (2) HAVE UNEVEN OR NO ILLUMINATION
WITH 24 VOLTS DC APPLIED.
Observe visually in darkened area.
a.
Replace overlay assembly (ref. para 5.1-16).
b.
Replace electrical wiring or contacts (ref.
para 5.1-16).
Change 1
5.1-11