TM 9-1240-401-34&P
Item No.
Item To Be Inspected
Procedures
6
CORRECTION COUNTER
Check light sources. Check that light is present and even throughout
the correction counter. Check that correction counter numbers are
clear and legible and that total excursion registers a minimum of 50 mils
at each stop.
7
ELEVATION COUNTER
Check light sources. Check that light is present and even throughout
the elevation counter. Check that elevation counter numbers are clear
and legible and register at least 1383 at maximum elevation and not
more than 9772 at maximum depression.
8
CROSS LEVEL KNOB
Operate cross-level knob. Check that operation is smooth without
binding or rough motion and that no more than 8 pound-inches
(0.904 N-m) of torque is required to rotate it.
Change 1
5.1-5