m. ELEVATION KNOB TORQUE INSPECTION
1 Using torque adapter (8213928) (Item 1, appx F)
and torque wrench, check that elevation knob (1)
running torque is 0.5 to 2.5 pound-inches (0.08 to
0.28 N-m).
2 If torque requirement is not met in step 1, repair
elevation mechanism (ref. para 5-17).
n. RESET COUNTER KNOB TORQUE INSPECTION
1 Using torque adapter (8599920) (Item 7, appx F)
and torque wrench on reset counter knob (1), push
in on reset knob and check that running torque is
no more than 2.5 pound-inches (0.28 N-m).
2 If torque requirement is not met in step 1, check
gearing and rotation for smooth movement.