b. VISUAL INSPECTION
1 Check that all screws and lockwashers are present
and tight.
2 Check that mounting surfaces are clean and free of
burrs.
3 Check that M117/M117A2 panoramic telescope is
free of dirt, corrosion, and foreign matter.
4 Check that paint is not chipped.
5 Check that all parts are present and free of dam-
age.
c. COLLIMATION
1 Set azimuth fixture ring (1) to zero.
2 Set gunner’s aid counter (2) to 00-00 detent.
3 Rotate reset counter knob (3) until reset counter (4)
registers 3200.
4 Sight through M117/M117A2 panoramic telescope
eyepiece (5) and turn azimuth knob (6) and eleva-
tion knob (7) until M117/M117A2 panoramic tele-
scope reticle is in coincidence with reticle of
collimating projector (8).
5 Check that azimuth counter (9) registers 3200. If
not, proceed as follows:
a.
Remove cap and insert screwdriver into slot-
ted shaft located below azimuth knob (6).
b. Push in and rotate screwdriver until azimuth
counter (9) registers 3200.
5-51