TM 9-1240-401-34&P
34
35
36
37
Install mechanical housing (6) on adapter assembly
(10).
Rotate gear shaft (7) until pinhole alines with gear on
mechanical housing (6) and install headless straight
pin (5).
Install machine screw (8) and two machine screws
(9). Tighten machine screws evenly to prevent
binding.
Install light conductor (4) on adapter assembly (10)
and secure with retaining strap (3), machine screw
(1), and new lockwasher (2).
5-24. RESET COUNTER ASSEMBLY 7660419 MAINTENANCE INSTRUCTIONS
This task covers:
a. Disassembly
b. Repair
c. Assembly
INITIAL SET-UP
Tools
Equipment Condition
Tool Kit, Electronic System, Repair, Field Maintenance
M117/M117A2 panoramic telescope removed from
(SC5180-95-CL-B29) 5180-01-168-0487
howitzer (TM 9-2350-311-10/TM 9-2350-314-10)
References
Counter assembly removed from M117/M117A2
TM 9-254
panoramic telescope (ref. para 5-22)
Reset counter assembly removed from adapter
assembly (ref. para 5-23)
Change 1
5-45


Back to Top