TM 9-1240-401-34&P
5.1-6. DIRECT SUPPORT INITIAL INSPECTION
Item No.
Item To Be Inspected
1
M15 QUADRANT
2
3
4
5
COUNTER WINDOWS
Check for moisture. Look for broken, cracked, or chipped glass.
CORRECTION KNOB
ELEVATION KNOB
LEVEL VIALS
Procedures
Look for signs of mistreatment, such as dents, scuff marks, bare spots,
and missing parts. Inspect M15 quadrant for cleanness.
Operate correction knob. Check that operation is smooth without
binding or rough motion and that not more than 3 pound-inches (0.339
N-m) of torque is required to turn it throughout its travel from stop to
stop.
Operate elevation knob. Check that operation is smooth without binding
or rough motion and that not more than 8 pound-inches (0.904 N-m) of
torque is required to turn it.
Check light sources. Check that light is present even throughout the
level vial. Check that level vial graduations are present and legible.
Check that level vials are not cracked or broken and that covers rotate
smoothly.
5.1-4