TM-9-1240-401-34-P

TELESCOPE MOUNT M146: M118A2 AND M118A3; TELESCOPE MOUNT M145: M145A1; PANORAMIC TELESCOPE: M117 AND M117A2; FIRE CONTROL QUADRANT: M15; PERISCOPE: M42

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

JULY 1993

  TM-9-1240-401-34-P - Page 241 of 590

TM 9-1240-401-34&P
Item No.
4
5
Item To Be Inspected
ELEVATION KNOB (4) AND
ELEVATION MECHANISM -
CONTINUED
CROSS-LEVEL KNOB (5) AND
CROSS LEVEL MECHANISM
Procedures
b.
c.
a.
b.
c.
Check elevation travel by turning elevation knob clockwise to
stop. Center elevation level vial bubble by turning handwheel on
upper section of cross-leveling fixture. Check that scale on upper
section of cross-leveling fixture reads at least 77° 47’ 37.5”. Turn
elevation knob counterclockwise to stop and center elevation level
vial bubble. Check that upper scale reads at least 12° 49’ 30”.
Check backlash by turning elevation knob clockwise to center
elevation level vial bubble. Turn counterclockwise past center
and then back to original position. Check that level vial bubble
centers again within 1/2 space between level vial graduations.
Check that torque required to turn elevation knob in either
direction does not exceed 8 pound-inches (0.904 N-m) at any
point between stops.
Check cross-level travel by turning cross-level knob to either stop.
Turn handwheel on lower section of cross-leveling fixture to center
cross-level vial bubble. Check that scale on lower section of
cross-leveling fixture reads at least 34°.
With cross-level vial bubble centered, turn cross-level knob
clockwise. Then turn back to original position to check backlash.
Check that cross-level vial bubble centers within 1/2 space
between level vial graduations.
Change 1
5.1-7