D.4.7 Cleaning.
Refer to para. 3.1.3 in Chapter 3 of this manual.
D.4.8 Visual Inspection.
a. Inspect external connector for damaged pins and foreign matter.
b. Inspect transceiver assembly for cracks, corrosion and damaged hardware.
c. Inspect transceiver assembly for damaged circuit cards and damaged or missing components.
d. Inspect antenna radome for scratches and pits. These conditions shall be acceptable providing the
laminated fiber is not cut, disturbed, or exposed.
e. Inspect gasket for deterioration, punctures, and tears.
f.
Inspect all wiring for bent or broken leads, cracked, frayed, deteriorated, worn, overheated or burnt
insulation, and secure attachment. Check lacing for secure attachment.
D.4.9 Repair.
Repair defective parts that were detected during preshop analysis (para. D.3) and visual
inspection (para. D.4.8).
D.4.1O Painting.
Refer to para. 3.1.5 in Chapter 3 of this manual.
D.4.11 Transceiver Assembly Reassembly.
D.4.11.1
ASSEMBLY OF EMI FILTER MODULE.
D.4.11.1.1 Configuration AY6707292-3 and AY6707292-4 Refer to Figures D-1 and D-2.
a. Insert the EMI filter module (32) into the transceiver assembly (1).
b. Install the protection cap’s (3) chain ring on the external connector.
c. Using connector pliers, secure the external connector with its nut.
d. Attach the EMI filter module (32) to the transceiver assembly (1) with screw (36) and flat washer
(37).
e. Plug connector (27) into plug P3 of MVP CCA (25) and secure the connector by fastening the two
locks.
f.
Install and fasten clamp (35) with screw (33) and flat washer (34).
D.4.11.1.2 Configuration AY6707292-5. Refer to Figure D-3.
a. Insert the EMI filter module (32) into the transceiver assembly (1).
b. Install the protection cap’s (3) chain ring on the external connector.
c. Using connector pliers, secure the external connector with its nut.
d. Attach the EMI filter module (32) to the transceiver assembly (1) with four screws (52) and four flat
washers (53).
e. Plug connector (27) into plug P3 of MVP CCA (25) and secure the connector by fastening the two
locks.
f.
Install and fasten clamp (35) with screw (33) and flat washer (34).
g. Install secure wire (43) using screw (44).