ARMY TM 9-1290-365-24&P
NOTE
Failure to perform continuity check at this point may require complete
disassembly of connector to correct improperly terminated connector pins.
m. Perform continuity test of cable in accordance with para. 3.3.6. If cable checks good,
proceed to step n.
n. Using small brush, clean sealing compound residue from threads of connector body (1 )
and backshell (2).
o. Apply primer to threads of connector body (1 j and backshell (2).
p. Apply sealing compound to threads of connector body (1 ) and backshell (2).
q. Screw backshell (2) on connector body (1) and torque to 3.7 in. Ib (5 N.m).
r. Apply S1184 adhesive to inside of boot (3) to bond with cable shield and backshell (2).
s. Apply S1125 adhesive inside of boot (3) for bonding to cable jacket (4) and backshell
(2).
t. Place boot (3) on backshell (2).
u. Using heat gun, apply heat uniformly to boot (3) until boot shrinks to form secure seal
around backshell (2) and cable (4).
3.3.5 Inspection
. Refer to Figure 3-4. Inspect Power and Data Cable (5-Meter) as follows:
a. Inspect all parts for damage, wear and deterioration.
b. Inspect all wiring for bent or broken leads; cracked, frayed, deteriorated, worn,
overheated, or burned insulation and security of attachment.
c. Inspect connectors for broken, bent, recessed, loose, damaged or missing pins.
3.3.6 Electrical Test.
3.3.6.1 TEST SETUP. Refer to Figure 3-5. Connect test setup as follows:
a. Set power supply to 5
±
0.5 VDC.
b. Turn off power supply.
NOTE
J3 turns counter clockwise to secure plug P3 of cable to tester.
c. Connect cable to Tester.
d. Connect oscilloscope to SCOPE entry in Tester.
e. Connect function generator to FUNCTION GEN entry in Tester.
f. Connect Power Supply to tester in correct polarity.
3-15