ARMY TM 9-1290-365-24&P
3.3.7 Fault Isolation Table
. Refer to Figures 3-7 and 3-8.
Table 3-9. Fault Isolation Table
Fault
at Para. 3.3.6.2 step
Fault Connectors
Pin and Wiring
Repair Procedure
f.
J2/A - P6/A
Check and replace J2 or
P6 connector
g.
J2B - P6B
Check and replace J2 or
P6 connector
h.
J2/C - J3/C
Check and replace J2 or J3
connector
i.
J3/E - P3/E
Check and replace J3 or
P3 connector
j.
J3/F - P3/ F
Check and replace J3 or
P3 connector
m.
J2/A,B or P6/A,B
Check and replace J2 or
P6 connector
n.
J1/A,B or P6/A,B
Check and replace J2 or
P6 connector
o.
J2/C or J3/C or P3/C
Only C1 on. Check and
replace P3. Only C2 ON.
Check and replace J3 both
are off. Check and replace
J2.
P.
J3/E,F P3/E,F
1553 Stub (see para. 3.3.8)
Check and replace J3, P3
or 1553 Stub (see para.
3.3.8)
q.
J3/E,F P3/E,F
1553 Stub (see para. 3.3.8)
Check and replace J3, P3
or 1553 Stub (see para.
3.3.8)
r.
J2/A,B,E,F,C
Check and replace J2
connector
t.
J2/E,F 1553 Stub T1
(see para. 3.3.8)
Check and replace J2
connector or 1553 Stub T1
(see para. 3.3.8)
u.
J3/E,F 1553 Stub T1
or R1, R2 (see para. 3.3.8)
Check and replace J3, P3
or 1553 Stub T1, R1, or R2
(see para. 3.3.8)
w.
1553 Stub T1
(see para. 3.3.8)
Check and replace 1553
Stub T1
(see para. 3.3.8)
3-20