3.4.5. Inspection
. Refer to Figure 3-10. Inspect 1553 Termination as follows:
a. Check all parts for damage, wear and deterioration.
b. Check all wiring for bent or broken leads; cracked, frayed, deteriorated, worn,
overheated, or burned insulation and security of attachment.
c. Check connector for broken, bent, recessed, loose, damaged or missing pins.
d. Check protective cap for security of attachment.
3.4.6. Continuity Test.
a. Check with DMM resistance between P1/F and P1/E.
b. Verify resistance is 75 ohms
±
1.0.
3.4.7. Removal.
a. Loosen attaching parts of 1553 Termination securing wire to gun.
b. Detach 1553 Termination from mating dummy connector on gun by loosening 1553
Termination connector.
3.4.8. Installation.
a. Attach 1553 Termination to dummy connector on gun.
b. Install securing wire of 1553 Termination to gun using attaching parts.
3-27