TM-9-1290-365-24-P

PALADIN MUZZLE VELOCITY SYSTEM M93 UPGRADED

TECHNICAL MANUAL; UNIT, DIRECT SUPPORT, AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

OCTOBER 2000

  TM-9-1290-365-24-P - Page 81 of 334

ARMY TM 9-1290-365-24&P
SECTION VI. TRANSCEIVER ASSEMBLY,
P/N 13002074
Section Contents
Subject
Page
General .
................................................................................................................................
3-33
Removal.
...............................................................................................................................
3-33
Installation.
............................................................................................................................
3-33
3.6. TRANSCEIVER ASSEMBLY, P/N 13002074
3.6.1. General
. The following paragraphs provide removal and installation procedures for the
M93 MVS, Transceiver Assembly, P/N 13002074. Source, maintenance, and recoverability
code is PAODD.
3.6.2. Removal
. Refer to Figure 3-12. Remove Transceiver Assy as follows:
a. Remove four screws (1 ) and four lockwashers (2) using 5-mm hex key wrench.
b. Remove Transceiver Assy (4) from Bracket Assy (3).
3.6.3. Installation
. Refer to Figure 3-12. Install Transceiver Assy to Bracket Assy as follows:
a. Attach Transceiver Assy (4) to Bracket Assy (3).
a. Install four screws (1 ) and four lockwashers (2) using 5-mm hex key wrench.
3.6.4. Disposition.
The Item Manager for the M93/M94 MVS provides 'Disposition' instructions
for serviceable/unserviceable spares, repairs or end item components. The procedure is
outlined in AR 725-50, Chapter 7, Nov 95 regarding submission of the item for repair. Any failed
item should be sent back to Borisch Manufacturing Corp. for repair/replacement. An FTE is
required for any returned items. The contract is DAAE20-98-C-0089. The repair facility
associated with the contract is:
Borisch Manufacturing Corporation
4511 East Paris Se
Grand Rapids, MI 49512
DODACC: CMASD8
RIC: CCA
Depending on the severity of the failure, it can take a maximum of three working weeks. If the
failure can’t be repaired, the item must be replaced with a new one at the unit’s expense. There
is no warranty for the MVS.
Change 1
3-33/(3-34 blank)