ARMY TM 9-1290-365-24&P
CHAPTER 6
STORAGE AND SHIPPING
CHAPTER CONTENTS
Subject
Page
Preparation for Storage.
..........................................................................................................
6-1
Environment.
...........................................................................................................................
6-1
Return to Service .
...................................................................................................................
6-1
Shipping.
.................................................................................................................................
6-2
6.1 PREPARATION FOR STORAGE.
This chapter describes procedures required for storing the M93 MVS. Refer to TM 740-90-1 for
instructions on placing the M93 MVS in administrative storage.
a. Prior to storage, the M93 will be wiped clean with a Lint Free Cloth (Item 7, Appx.F) or
with a Wiping Rag (Item18, Appx. F) dampened with Isopropyl Alcohol (Item 4, Appx. F).
b The Receiver-Transmitter microstrip antenna on the face of the antenna must be
protected from damage with bubble wrap to prevent damage during
storage or shipment.
c. When stored in the howitzer, the antenna-bracket assembly will have the antenna face
protected with bubble wrap and be secured in place with webstraps to prevent damage
due to shifting of equipment
during movement of the howitzer.
d. When stored elsewhere, it should be stored in a cool, dry location if possible.
6.2 ENVIRONMENT
Once prepared for storage, the M93 MVS may be stored indefinitely in an environment suitable
for electronic equipment. Maximum and minimum environmental conditions are as follows:
Maximum Temperature
+150
°
F
Minimum Temperature
-50
°
F
Relative Humidity
95%
6.3 RETURN TO SERVICE.
To return an M93 MVS to service after storage, perform the following procedures:
a. Perform external inspection in accordance with para 3.1.4.
b. Install the M93 MVS to the Paladin Automatic Fire Control System (AFCS) and verify
proper operation. Refer to TM 9-2350-314-10.