b. Removal.
1.
Using spanner wrench, unscrew and take off electrical connector (l). Cover
connector and mating receptacle (2) wit h protective caps.
2.
Using 9/16-inch wrench, unscrew and take off bolt, lockwasher, and key
washer ( 3).
3.
Pull adjustment bracket (4) up and away from generator (5).
4.
Push generator toward engine and take two V-belts (6) off pulley (7).
GO TO FRAME 2
TA 047101