TM 9-2320-209-20-3-1
FRAME 4
1.
Push generator (1) toward firewall as shown. Front flange on generator
must be hard against front flange on mounting bracket (2).
2.
Put 0.005-inch feeler gage between rear flange on generator (1) and shims
between rear flange on mounting bracket (2). Feeler gage should fit between
flanges very easily.
NOTE
Hold rear of generator (1) up when sliding bolt (3)
out of flange to put in shims (4).
3.
Pull bolt (3) out of rear flange on generator (1). Slip shims (4) between
generator flange and rear flange on mounting bracket (2). Put bolt back in.
4.
Do steps 1, 2 and 3 again as necessary,
adding shims (4) until feeler gage
makes snug fit between shims (4) and rear flange on generator (1).
5.
Screw two nuts (5) on bolts (3 and 6) finger tight.
6.
Using torque wrench, tighten nuts (5) to 65 to 70 pound-feet.
GO TO FRAME 5
7-9