TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 441 of 830

TM 9-2320-209-20-3-1
FRAME 4
1.
Using mechanical puller (1), set adjustable arms (2) of puller over rear edge of
generator pulley (3) as shown.
2.
Screw puller bolt (4) in until it presses against generator shaft (5) as shown.
3.
Using 3/4-inch socket wrench,
slowly tighten puller bolt (4) until generator
pulley (3) is loose on shaft (5).
Pulley will move in direction shown.
4.
Take puller (1) off generator pulley (3) and slide pulley off end of shaft (5).
5.
Tape key (6) to shaft (5) so it will not be lost.
END OF TASK
7-5