TM-9-2320-209-20-3-1

2½-TON, 6X6, M44A1 AND M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; TROUBLESHOOTING; ORGANIZATIONAL LEVEL; VOLUME 3 OF 3; PART 1 OF 4

MAY 1981

  TM-9-2320-209-20-3-1 - Page 447 of 830

TM 9-2320-209-20-3-1
d.
Polarization.
FRAME 1
1.
Using spanner wrench, unscrew and take off chassis wiring harness connector
(1) from voltage regulator (2).
CAUTION
Make sure connector (1)
Pin A on connector goes
terminal.
2.
Reconnect battery ground cable.
GO TO FRAME 2
pins do not touch on the engine.
directly to positive battery
Refer to para 7-58.
7-11


Back to Top