TM 9-2320-209-20-3-1
FRAME 3
1.
Using spanner wrench, join chassis wiring harness connector (1) to voltage
regulator receptacle (2) and tighten connector.
2.
Using spanner wrench, join generator connector (3) to generator receptacle
(4) and tighten connector.
3.
Reconnect battery ground cable. Refer to para 7-58.
END OF TASK