TM 9-2320-209-20-3-1
FRAME 2
1.
2.
3.
4.
5.
Put male
WARNING
Be very careful when using jumper wires (2). Shorting
wire to ground can burn connector pins or wiring and
cause injury to personnel and damage to equipment.
pin (1) of jumper wire (2) into pin B of generator receptacle (3).
Put female connector (4) of jumper wire (5) onto pin A of chassis wiring
harness connector (6).
Holding jumper wire (2) in one hand and jumper wire (5) in the other,
briefly strike wires together. Do not let them stay together.
NOTE
Chassis wiring harness connector (6) was taken off voltage
regulator at start of task.
Disconnect battery ground cable. Refer to para 7-58.
Take away jumper wires (2 and 5).
GO TO FRAME 3
7-12