Table 2-1. Unit Level Preventive Maintenance Checks and Services (Contd).
ITEM TO
‘EM
INTERVAL
CHECK/
NOT FULLY
NO.
PROCEDURE
MISSION
SERVICE
CAPABLE IF:
EXPECTED TEMPERATURES
LUBRICANTS
ABOVE 15°F
+40°F TO -15°F
+4°F TO -65°F
(ABOVE -9°C)
(+4°C TO -26°C)
(+4°C TO -54°C)
GAA
-
Grease, automotive and artillery
All Temperatures
(MIL-G-10924)
46
Semi-
Trunnion
Every 6 months or 3,000 mi (4,827 km), whichever occurs
annual
first, loosen screws (1) on trunnion bearing cap (2),
lubricate with GAA through fitting (3) until lubricant
appears around cap (2), and tighten capscrews (1).
47
Semi-
Van
a.
Make a general inspection of the van body. Inspect
annual
body
and operate heater, air conditioner, ventilators, dome
(All)
lights, and switches to ensure proper operation.
b.
Inspect electrical wiring for frays, splits, and loose
Electrical wiring
terminals. Repair as necessary (para. 4-42).
is frayed, split;
terminals are
loose.
c.
Lubricate fitting (5) on pawl plunger (4) with GAA.