TM 9-2320-260-20
Table 2-1. Unit Level Preventive Maintenance Checks and Services (Contd).
ITEM TO
NOT FULLY
ITEM INTERVAL
CHECK/
PROCEDURE
MISSION
NO.
SERVICE
CAPABLE IF:
EXPECTED TEMPERATURES
LUBRICANTS
ABOVE 15°F
+40°F TO -15°F
+40°F TO -65°F
(ABOVE -9°C)
(+4°C TO -26°C)
[+4°C TO -54°C]
GAA -
Grease, automotive
and artillery
All Temperatures
(MIL-G-10924)
OE/HDO -
Lubricating oil, internal
OE/HDO 30
OE/HDO 10
OEA
combustion engine
(MIL-L-2104)
OEA -
Lubricating oil, internal
combustion engine (arctic)
(MIL-L-46167)
42
Semi-
Frame,
c. Welded Frame Connections.
annual
cross-
1. Perform inspection of welded frame connections.
members,
Where welds are found on vehicle, check for integrity,
and fifth
deterioraton, and flaking.
wheel
(Contd)
2. Check spare tire carrier for security, completeness
of assembly, and proper operation. Replace if damaged
(paras. 12-8, 12-14, 12-46, 12-65, or 12-72).
3. Check operation of towing pintle hook (3). Inspect
Pintle or bracket
pintle (4) and bracket (1) for cracks and breaks. Replace
is cracked
or
if cracked or broken (para. 10-9, 10-10, or 10-11).
broken.
4. Lubricate pintle hook fittings (2) with GAA every
3,000 mi (4,827 km).
2-32


Back to Top