FUEL PUMP METERING VALVE REMOVAL
1.
Remove nut (Figure 2, Item 5) and wires (Figure 2, Item 4) from terminal (Figure 2, Item 6).
2.
Remove two screws (Figure 2, Item 1), lockwashers (Figure 2, Item 2), and washers (Figure 2, Item 3) from
fuel pump metering valve (Figure 2, Item 7). Discard lockwashers.
3.
Remove fuel shutoff valve (Figure 2, Item 7) and preformed packing (Figure 2, Item 8) from fuel pump
(Figure 2, Item 9). Plug openings in fuel pump. Discard preformed packing.
M9452DAA
1
2
3
4
5
6
7
8
9
Figure 2.
Fuel Pump Metering Valve Removal.
END OF TASK