MANUAL SHUTOFF VALVE INSTALLATION
1.
Install manual fuel shutoff valve (Figure 4, Item 4) in fuel shutoff valve (Figure 4, Item 6).
2.
Install control cable (Figure 4, Item 5) on shutoff lever (Figure 4, Item 2) with clip (Figure 4, Item 1) and screw
(Figure 4, Item 7). Ensure shutoff lever is in forward position.
3.
Connect fuel line (Figure 4, Item 3) to manual fuel shutoff valve (Figure 4, Item 4).
M9454DAA
7
1
2
3
4
5
6
Figure 4.
Manual Shutoff Valve Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Start engine and check fuel pump shutoff valves for proper operation. (TM 9-2320-272-10)
2.
Install left splash shield. (TM 9-2320-272-10)
END OF TASK
END OF WORK PACKAGE