ETHER VALVE REMOVAL
CAUTION
When ether cylinder is removed, cover must be installed to prevent dust or dirt from
entering
valve.
NOTE
Tag wires for installation.
1.
Disconnect wire (Figure 2, Item 7) from ether valve wire (Figure 2, Item 6).
2.
Disconnect ether supply tube (Figure 2, Item 8) from ether valve adapter (Figure 2, Item 9).
3.
Remove two locknuts (Figure 2, Item 5), screws (Figure 2, Item 2), ground wire (Figure 2, Item 3), ether valve
bracket (Figure 2, Item 4), and ether valve (Figure 2, Item 10) from ether cylinder bracket (Figure 2, Item 1).
Discard locknuts.
7
M9532DAA
6
5
4
3
2
8
9
10
1
Figure 2.
Ether Valve Removal.
END OF TASK
TM 9-2320-272-23-2
0263
0263-4